Features:
High efficiency, high reliability
Universal AC input/ full range
100% full load burn-in test
Protections: Short circuit/ Over load/ Over voltage
Forced air cooling by built in DC fan
Built-in cooling Fan ON-OFF control
Fixed switching frequency at 110KHz
Built-in active PFC function, remote ON-OFF control, remote
sense function
3 years warranty
Dimensions:170*120*93mmㄗL*W*Hㄘ |
760)this.width=760;" src="http://www.chnwh.com/manage/jksm_upfile/2008614170854.gif" onload="ㄕ#106avascript:if(this.width>760)this.width=760;" align=absMiddle border=0> | | |
Model |
P-500 |
|
12 |
13.5 |
15 |
24 |
27 |
48 |
DC Voltage |
12V |
13.5V |
15V |
24V |
27V |
48V |
Voltage Tolerance |
㊣1% |
㊣1% |
㊣1% |
㊣1% |
㊣1% |
㊣1% |
Rated Current |
40A |
36A |
32A |
20A |
18A |
10A |
Current Range |
0ㄜ40A |
0ㄜ36A |
0ㄜ32A |
0ㄜ20A |
0ㄜ18A |
0ㄜ10A |
Rated Power |
480W |
486W |
480W |
480W |
486W |
480W |
Ripple & Noise |
240mVp-p |
240mVp-p |
240mVp-p |
240mVp-p |
200mVp-p |
300mVp-p |
DC Adjustment Range |
-16%,+10% |
-12%,+15% |
-10%,+20% |
-16%,+10% |
-12%,+11% |
-15%,+16% |
Setup,Rise,Hold Time |
1.5s,50ms,20ms at full load | |
INPUT |
|
Voltage Range |
88‵264 VAC47‵63 Hz˙124‵370VDC |
Power Factor |
PF>0.95/230VACPF>0.95/115VAC at full load |
AC Current |
7A/115 V3.5A/ 230 V |
Efficiency |
84%ㄗSKSP-500-12); 84%ㄗSKSP-500-13.5); 83%ㄗSKSP-500-15); 85.5%ㄗSKSP-500-24); 86.5%ㄗSKSP-500-27); 87%ㄗSKSP-500-48); |
Inrush Current |
18A/115V36A/230V |
Leakage Current |
ˉ3.5mA/240VAC |
PROTECTION |
|
Over Load |
105%‵135% |
|
Protection type: Fold back current limiting, recovers automatically after fault condition is removed. |
Over Voltage |
115%‵135% |
|
Protection type: hiccup mode, recovers automatically after fault condition is removed. |
Over Temp. |
RTH1 OR RTH2≡50⊥ FAN ONㄛ≒45⊥ FAN OFFㄛ≡70⊥ output shutdown |
ENVIRONMENT |
|
Working Temp., Humidity |
-10⊥‵+50⊥˙20%‵90 %RH |
Storage Temp., Humidity |
-20⊥‵+85⊥˙10%‵95 %RH |
Vibration |
10‵500Hzㄛ2G 10min./1cycleㄛperiod for 60min, each along X, Y, Z axes |
SAFETY |
|
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
STANDARD |
|
Safety Standard |
Design refer to UL1950,TUV EN60950 |
EMC Standard |
Design refer to EN55022ㄛEN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204 |
OTHERS |
|
Weight |
1.9Kg |
Packing |
8pcs/15.2kg/1.06CUFT |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25⊥ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12∪twisted pair-wire terminated with a 0.1米 &47米parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | | |