Features:
High efficiency, high reliability
Universal AC input/ full range
Built-in active PFC function, PF>0.93/230VAC
100% full load burn-in test
Protections: Short circuit/ Over load/ Over voltage/ Over temperature
Built-in remote ON-OFF control and remote sense function
Forced air cooling by built-in DC fan
3 years warranty
Dimensions: 268*127*50mm(L*W*H) |
760)this.width=760;" src="http://www.chnwh.com/manage/jksm_upfile/2008614170407.gif" onload="ㄕ#106avascript:if(this.width>760)this.width=760;" align=absMiddle border=0> | | |
|
Model |
P-501-5 |
P-501-12 |
P-501-13.5 |
P-501-15 |
P-501-24 |
P-501-27 |
P-501-48 |
|
DC Voltage |
5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
|
Voltage Tolerance |
㊣2% |
㊣1.5% |
㊣1.5% |
㊣1.5% |
㊣1.0% |
㊣1.0% |
㊣1.0% |
|
Rated Current |
85A |
42A |
37A |
34A |
21A |
18.5A |
11A |
|
Current Range |
0ㄜ85A |
0ㄜ42A |
0ㄜ37A |
0ㄜ34A |
0ㄜ21A |
0ㄜ18.5A |
0ㄜ11A |
|
Rated Power |
425W |
504W |
499.5W |
510W |
504W |
499.5W |
528W |
|
Ripple & Noise |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
250mVp-p |
|
DC Adjustment Range |
㊣10% |
㊣10% |
㊣10% |
㊣10% |
㊣10% |
㊣10% |
㊣10% |
|
Setup,Rise,Hold Time |
1000ms,80ms,20ms at full load | |
| INPUT |
|
| Voltage Range |
90‵264VACㄗ5Vㄩ85‵264VACㄘ47‵63 Hz˙selected by switch 120‵370VDC |
| Power Factor |
PF>0.93/230VAC |
| AC Current |
7A/115 VAC3.5A/230VAC |
| Efficiency |
78%ㄗHSP-501-5); 84%ㄗHSP-501-12); 84%ㄗHSP-501-13.5); 84%ㄗHSP-501-15); 85%ㄗHSP-501-24); 85%ㄗHSP-501-27); 86%ㄗHSP-501-48); |
| Inrush Current |
Cold start 40A /230VAC |
| Leakage Current |
<1.5mA/ 264VAC/60Hz |
| PROTECTION |
|
| Over Load |
110%~130% |
|
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage |
110%~130% |
|
Protection type: Shut down o/p voltage, re-power on to recover |
| Over Temp. |
When TSW1≡80⊥ㄛTSW2≡90⊥ |
|
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10⊥‵+50⊥˙20%‵90 %RH |
| Storage Temp., Humidity |
-20⊥‵+85⊥˙10%‵95 %RH |
| Vibration |
10‵500Hzㄛ2G 10min./1cycle, period for 60min, X, Y, Z axes |
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| STANDARD |
|
| Safety Standard |
UL60950-1, EN60950-1 |
| EMC Standard |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204ㄛEN61000-6-2 |
| OTHERS |
|
| Weight |
1.7Kg |
| Packing |
6pcs/11.3g/0.67CUFT |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25⊥ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12∪twisted pair-wire terminated with a 0.1米 &47米 parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | | |