Features:
Universal AC input/ full range
Built-in active PFC function, PF>0.93
100% full load burn-in test
Protections: Short circuit/ Over load / Over voltage/ Over temperature
Built- in constant current limiting circuit
LED indicator for power on
Remote ON-OFF control ( Optional )
Fixed switching frequency at PF: 67KHzPWM: 134KHz
3 years warranty
Dimensions: 199*99*50mmㄗL*W*Hㄘ |
760)this.width=760;" src="http://www.chnwh.com/manage/jksm_upfile/2008614163542.gif" onload="ㄕ#106avascript:if(this.width>760)this.width=760;" align=absMiddle border=0> | | |
Model |
P-150 |
|
3.3 |
5 |
7.5 |
12 |
13.5 |
15 |
24 |
27 |
48 |
DC Voltage |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
Voltage Tolerance |
㊣2% |
㊣2% |
㊣2% |
㊣2% |
㊣2% |
㊣2% |
㊣1% |
㊣1% |
㊣1% |
Rated Current |
30A |
30A |
20A |
12.5A |
11.2A |
10A |
6.3A |
5.6A |
3.2A |
Current Range |
0ㄜ30A |
0ㄜ30A |
0ㄜ20A |
0ㄜ12.5A |
0ㄜ11.2A |
0ㄜ10A |
0ㄜ6.3A |
0ㄜ5.6A |
0ㄜ3.2A |
Rated Power |
66W |
100W |
101.25W |
102W |
101.25W |
100.5W |
100.8W |
102.6W |
100.8W |
Ripple & Noise |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
150mVp-p |
150mVp-p |
250mVp-p |
DC Adjustment Range |
-5%ㄛ+10% |
Setup,Rise,Hold Time |
600ms,30ms,20ms at full load |
|
|
INPUT |
|
Voltage Range |
85‵264 VAC47-63Hz˙120‵370VDC |
Power Factor |
PF>0.93/230VAC,PF>0.98/115VAC at full load |
AC Current |
2.5A/115 VAC1.2A/230VAC |
Efficiency |
67%ㄗHSP-150-3.3); 75%ㄗHSP-150-5); 79%ㄗHSP-150-7.5); 80%ㄗHSP-150-12); 80%ㄗHSP-150-13.5); 81%ㄗHSP-150-15); 83%ㄗHSP-150-24); 84%ㄗHSP-150-27); 84%ㄗHSP-150-48); |
Inrush Current |
Cold start 40A/230VAC |
Leakage Current |
<2mA/240VAC |
PROTECTION |
|
Over Load |
105%~150% |
|
Protection type: Constant current limiting, recovers automatically after fault condition is recover |
Over Voltage |
110%~135% |
|
Protection type: Shut down o/p, re-power on to recover |
Over Temp. |
TSW1ㄗPower transistorㄘWhen temp.in 95㊣5 ⊥ shutdown o/p voltagetemp. ˉ95㊣5 ⊥O/I auto-recovery. |
Function |
|
Remote Control(Optional) |
CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF |
ENVIRONMENT |
|
Working Temp., Humidity |
-10⊥‵+60⊥˙20%‵90 %RH |
Storage Temp., Humidity |
-20⊥‵+85⊥˙10%‵95 %RH |
Vibration |
10‵500Hzㄛ2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
SAFETY |
|
Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
STANDARD |
|
Safety Standard |
Design refer to UL1950,TUV EN60950 |
EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
OTHERS |
|
Weight |
0.75Kg |
Packing |
20pcs/15Kg/1.28CUFT |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25⊥ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12∪twisted pair-wire terminated with a 0.1米 &47米 parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | | |