Model |
CN-1K2-5 |
CN-1K2-12 |
CN-1K2-15 |
CN-1K2-24 |
CN-1K2-48 |
DC Voltage |
5V |
12V |
15V |
24V |
48V |
Voltage Tolerance |
㊣2.1% |
㊣1% |
㊣1% |
㊣1% |
㊣1% |
Rated Current |
180A |
100A |
80A |
50A |
24A |
Current Range |
0ㄜ180A |
0ㄜ100A |
0ㄜ80A |
0ㄜ50A |
0ㄜ24A |
Rated Power |
900W |
1200W |
1200W |
1200W |
1200W |
Ripple & Noise |
100mVp-p |
120 mVp-p |
150 mVp-p |
240mVp-p |
480mVp-p |
DC Adjustment Range |
Can adjust from 20%~100% output voltage by external control 1-5V |
Setup,Rise,Hold Time |
800ms, 50ms, 16ms at full load | |
INPUT |
|
Voltage Range |
200‵260 VAC47‵63 Hz˙ 290‵370VDC |
AC Current |
11A/ 230 VAC |
Efficiency |
77%(HSCN-1K2-5); 83%(HSCN-1K2-12); 85%(HSCN-1K2-15); 85%(HSCN-1K2-24); 87%(HSCN-1K2-48); |
Inrush Current |
120A/230V |
Leakage Current |
3.5 mA/240VAC |
PROTECTION |
|
Over Load |
101%‵115%(HSCN-1K2-5); 110%‵135%(HSCN-1K2-12; HSCN-1K2-15; (HSCN-1K2-24; HSCN-1K2-48); |
|
Protection type: Current limiting, delay shut down o/p voltage, re-power on to recover |
Over Voltage |
110%~135% |
|
Protection type: Shut down o/p voltage, re-power on to recover |
Over Temp. |
TSW1ㄗPower transistorㄘWhen temp.>100 ⊥, shut down o/p voltage, re-power on to recover |
ENVIRONMENT |
|
Working Temp., Humidity |
-10⊥‵+65⊥ㄛ20%‵90 %RH |
Storage Temp., Humidity |
-20⊥‵+85⊥ㄛ10%‵95 %RH |
Vibration |
10‵200Hzㄛ2G 10min./1cycle, period for 60min, each along X, Y, X axes |
SAFETY |
|
Withstand Voltage |
I/P-O/P, I/P-FG:1500VAC |
Isolation Resistance |
I/P-O/P, I/P-FG, >100M Ohms / 500VDC |
STANDARD |
|
Safety Standard |
Ddsign refer to UL1950,CSA22.2,IEC60950 |
EMC Standard |
Design refer to FCC Part 15 Class A |
OTHERS |
|
Weight |
4.5Kg |
Packing |
4pcs/20kg/CARTON |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25⊥ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12∪twisted pair-wire terminated with a 0.1米 &47米parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | | |