Model |
CN-600-5 |
CN-600-12 |
CN-600-15 |
CN-600-18 |
CN-600-24 |
CN-600-48 |
DC Voltage |
5V |
12V |
15V |
18V |
24V |
48V |
Voltage Tolerance |
㊣1.5% |
㊣1% |
㊣1% |
㊣1% |
㊣1% |
㊣1% |
Rated Current |
100A |
50A |
40A |
33A |
25A |
12A |
Current Range |
0ㄜ100A |
0ㄜ50A |
0ㄜ40A |
0ㄜ33A |
0ㄜ25A |
0ㄜ12A |
Rated Power |
500W |
600W |
600W |
600W |
600W |
600W |
Ripple & Noise |
100mVp-p |
120 mVp-p |
150 mVp-p |
180 mVp-p |
240mVp-p |
480mVp-p |
DC Adjustment Range |
Can adjust from 20%~100% output voltage by external control 1-5V |
Setup,Rise,Hold Time |
800ms, 50ms, 16ms at full load |
|
|
INPUT |
|
Voltage Range |
90‵130VAC / 180‵260 VAC47‵63 Hz˙selected by switch 260‵370VDC |
AC Current |
11 A/115 VAC 7.0A/ 230 VAC |
Efficiency |
77%(HSCN-600-5); 80%(HSCN-600-12); 81%(HSCN-600-15); 82%(HSCN-600-18); 85%(HSCN-600-24); 87%(HSCN-600-48); |
Inrush Current |
60A/230V |
Leakage Current |
3.5 mA/240VAC |
PROTECTION |
|
Over Load |
101~115%(HSCN-600-5); 110%‵135%(HSCN-600-1); HSCN-600-15; (HSCN-600-18;HSCN-600-24; HSCN-600-48) |
|
Protection type: Current limiting, delay shut down o/p voltage, re-power on to recover |
Over Voltage |
110%~135% |
|
Protection type: Shut dwon o/p voltage, re-power on to recover |
Over Temp. |
TSW1ㄗPower transistorㄘWhen temp. >100 ⊥, shut down o/p voltage, re-power on to recover |
ENVIRONMENT |
|
Working Temp., Humidity |
-10⊥‵+65⊥ㄛ20%‵90 %RH |
Storage Temp., Humidity |
-20⊥‵+85⊥ㄛ10%‵95 %RH |
Vibration |
10‵200Hzㄛ2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
SAFETY |
|
Withstand Voltage |
I/P-O/P, I/P-FG:1500VAC |
Isolation Resistance |
I/P-O/P, I/P-FG, 100M Ohms / 500VDC |
STANDARD |
|
Safety Standard |
Design refer to UL1950,CSA22.2,IEC60950 |
EMC Standard |
Design refer to FCC Part 15 Class A |
OTHERS |
|
Weight |
2.3Kg; |
Packing |
8pcs/24.0kg/CARTON |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25⊥ of ambient temperature. |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12∪twisted pair-wire terminated with a 0.1米 &47米 parallel capacitor. |
3.Tolerance: includes set up tolerance, line regulation and load regulation |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |