Feature: |
|
|
|
|
High efficiency, high reliability Universal AC input / full range 100% full load burn-in test Short circuit / overload / over-voltage protection Cooling by free air convection 2 years warranty Dimension: 159*97*38mm |
760)this.width=760;" src="http://www.chnwh.com/manage/jksm_upfile/2008614153102.gif" onload="ㄕ#106avascript:if(this.width>760)this.width=760;" align=absMiddle border=0>
|
|
Case No.ㄩH003 | |
|
MODEL |
T-60A |
T-60B |
T-60C |
|
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
CH1 |
CH2 |
CH3 |
|
OUTPUT |
DC VOLTAGE |
5V |
12V |
-5V |
5V |
12V |
-12V |
5V |
15V |
-15V |
|
VOLTAGE TOLERANCE |
㊣2% |
㊣6% |
㊣6% |
㊣2% |
㊣6% |
㊣6% |
㊣2% |
㊣6% |
㊣6% |
|
RATED CURRENT |
5A |
2.5A |
0.5A |
5A |
2.5A |
0.5A |
5A |
2A |
0.5A |
|
CURRENTRANGE |
0.5-7A |
0.2-3.5A |
0-1A |
0.5 -7A |
0.2-3.5A |
0-1A |
0.5-7A |
0.2-3A |
0-1A |
|
RATED POWER |
57.5W |
61W |
62.5W |
|
RIPPLE &NOISE(MAX) |
100
mVp-p |
100
mVp-p |
100
mVp-p |
100
mVp-p |
100
mVp-p |
100
mVp-p |
100 mVp-p |
100mVp-p |
100
mVp-p |
|
DC VOLTAGEFRE QUENCY RANGE |
CH1ㄩ+10,-5% |
|
SETUP,RISE,HOLD TIME |
800ms,50ms,10ms/115VAC300ms, 50ms, 80ms/230VAC |
|
INPUT |
VOLTAGERANGE |
85‵264 VAC47-63Hz˙120‵370VDC |
|
AC CURRENT |
2A/115 V1A/ 230 V |
|
EFFICIENCY |
69% |
72% |
72% |
|
INRUSH CURRENT |
Cold start 30A/115V60A/230V |
|
LEAKAGE CURRENT |
ˉ1mA/240VAC |
|
PROTECTION |
OVERLOAD PROTECTION |
105%‵150%Fold back current limiting, recovers automatically |
|
OVER-VOLTAGE PROTECTION |
|
|
HIGH TEMPERATURE PROTECTON |
﹝﹝﹝ |
|
ENVIRONMENT |
WORKING TEMP.& HUMIDITY |
-10⊥‵+50⊥˙20%‵90 %RH |
|
STORAGE TEMP.& HUMIDITY |
-20⊥‵+85⊥˙10%‵95 %RH |
|
VIBRATION |
10‵500Hzㄛ2G 10min./1cycle, period for 60min, each along X.Y.Z axes |
|
SAFETY |
WITHSTAND VOLTAGE |
I/P-O/Pㄩ3KVACI/P-FGㄩ1.5KVACO/P-FGㄩ0.5KVAC |
|
ISOLATION RESISTANGE |
I/P-O/P, I/P-FG, O/P-FGㄩ500VDC/100M次 |
|
STANDARDS |
SAFETY STANDARDS |
Design refer to UL1012, EN60950 |
|
EMC STANDARDS |
|
|
OTHERS |
WEIGHT |
0.55Kg |
|
PACKING |
30pcs/17.4Kg/1CUFT |
|
NOTE |
1. Tolerance: Includes set up tolerance, line regulation and load regulation.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12§ twisted pair-wire teminated with a
0.1米f & 47米f parallel capacitor.
3. All output can achieve the max. current, but full load can not exceed the max. output power. | | |