High efficiency, high reliability, small size Universal AC input / full range 100% full load burn-in test Short circuit / overload protection Cooling by free air convection 1 year warranty Dimension: 99*82*36mm(L*W*H ) |
760)this.width=760;" src="http://www.chnwh.com/manage/jksm_upfile/200861490550.jpg" onload="£¦#106avascript:if(this.width>760)this.width=760;" align=absMiddle border=0>
|
|
MODEL |
M-35-12 |
M-35-15 |
M-35-24 |
M-35-48 |
|
OUTPUT |
DC VOLTAGE |
12V |
15V |
24V |
48V |
|
VOLTAGE TOLERANCE |
¡À1% |
¡À1% |
¡À1% |
¡À1% |
|
RATED CURRENT |
3A |
2.4A |
1.5A |
0.8A |
|
CURRENTRANGE |
0-3A |
0-2.4A |
0-1.5A |
0-0.8A |
|
RATED POWER |
36W |
36W |
36W |
38.4W |
|
RIPPLE &NOISE(MAX) |
120mVp-p |
120mVp-p |
200mVp-p |
240mVp-p |
|
DC VOLTAGEFRE QUENCY RANGE |
¡À10% |
¡À10% |
¡À10% |
¡À10% |
|
SETUP,RISE,HOLD TIME |
200ms,100ms,20ms |
|
INPUT |
VOLTAGERANGE |
170¡«264VAC 47¡«63 Hz£»240¡«370VDC |
|
AC CURRENT |
0.65A/ 230 V |
|
EFFICIENCY |
81% |
81% |
83% |
83% |
|
INRUSH CURRENT |
ÀäÆô¶¯µçÁ÷36A/230V |
|
LEAKAGE CURRENT |
£¼1 mA/240VAC |
|
PROTECTION FEATURES |
OVERLOAD PROTECTION |
110%¡«160% |
|
ENVIRONMENT |
WORKING TEMP.& HUMIDITY |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
|
STORAGE TEMP.& HUMIDITY |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
|
VIBRATION |
10¡«500Hz£¬2G 10min./1 cycle£¬period for 60min£¬each alongX,Y,Z axes |
|
SAFETY |
WITHSTAND VOLTAGE |
I/P-O/P£º2KVAC I/P-FG£º1.5KVAC O/P-FG£º0.5KVAC |
|
ISOLATION RESISTANGE |
I/P-O/P, I/P-FG, O/P-FG£º100M 0hms/500VDC |
|
STANDARDS |
SAFETY STANDARDS |
Design refer to UL1012 |
|
EMC STANDARDS |
Design refer toEN55022 CLASSA |
|
OTHERS |
WEIGHT |
0.3Kg |
|
PACKING |
60pcs/18Kg/0.9CUFT |
|
NOTE |
1. Tolerance: Includes set up tolerance, line regulation and load regulation.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12¡± twisted pair-wire teminated with a
0.1¦Ìf & 47¦Ìf parallel capacitor |